Owner Manual

Humidex
4
Pre-Installation
Included Components
Before installing your Humidex, make sure that you have the right model and accessories. The
following items should be included in the accessory box. If parts are missing, contact our customer
service at US 1-888-533-1348, Can. 1-800-416-9111.
1x Owner’s Manual
1x Cover Plate
6x #8 x 9/16” Screws
1x Warranty Card
2x Cable Ties
4x #8 x 1¼” Truss Screws
1pc. Aluminum Tape
1x Vinyl Flex 6” x 24”
**2x 4” x 12” Toe Space Grill
1x Exhaust Vent 6”
4x #8 x 2” Screws
1x Checklist
4x Plastic Anchors
** Only included with DVS-CS and DVS-CH Models
Additional grilles for replenishment air and interior rooms not included.
Tools Required for Installation
- Electric reciprocal or hole saw 6¼”
- Drill with a ¼” concrete bit
- Phillips or Robinson Screw Driver
- Measuring Tape
- Hammer
- Pencil
For concrete, cinderblock or brick installation, use a hammer drill with chiseling ability ½” x 16”
long and a chisel bit 1” thick.
Key Installation Facts
1) Unit must be installed at floor level approximately 3” off the floor.
2) Replenishment air has to flow from upstairs into the basement or crawlspace. Open doors
that can be closed are not a substitute for a properly installed vent.
3) Unit should be installed as far away as possible from the source of replenishment air.
4) Outside duct must be no less than 6” and dedicated for the Humidex unit only.
5) Maximum circulation is required to draw in air from all parts of the basement.
6) Unit should not be installed within 8 feet of combustion appliance.
IMPORTANT What Not to Do
1) DO NOT install the unit more than approx. 3 inches off the floor.
2) DO NOT make more than one turn with the duct and the ductwork should not be longer than 3
feet in total, unless rigid ducting is used - see Ducting, Page 6.
3) DO NOT crush the vinyl Pipe.
4) DO NOT install the unit next to a replenishment air supply.