Full Product Manual

Humidex
25
COLD SURFACE FACTS IMPORTANT
Before the Humidex is installed, cold ducts and pipes should be insulated as per proper HVAC
protocols to reduce possible condensation.
Control Set-up and Location
Once the exhaust unit has been mounted and powered, the control will need to be paired. To complete
the pairing process, the control should be powered next to the exhaust using the provided DC power
block. The following steps will allow your control to be paired to your exhaust.
1) Power the myHome control unit next to HCS exhaust. (Keep the HCS Exhaust Unplugged)
2) The control will prompt you to unplug your HCS exhaust unit, once done confirm on
control
3) The control will prompt you to plug your HCS exhaust, once done confirm on control
4) Control and Exhaust should now be paired, if pairing process did not work, power off both
unit and repeat the pairing process.
5) If a Booster was purchased, it can then be plugged in and will automatically pair with your
exhaust.
Note: Steps 2 and 3 can take upwards to a minute to complete.
Once the control is configured and the system has been paired, you must now find a location for the
control. The HCS myHome control must be located on the main floor and above the exhaust unit as
much as possible while trying to stay away direct sunlight and other sources of heat.
DO NOT mount the control to the wall until setup is completed.
The control can either be placed on a flat surface by using the Desk Stand that is provided or can be
mounted to the wall if desired. A mounting template is provided to assist in placing the mounting
anchors and screws at the appropriate location.
2 USB power ports are located on the Control to allow multiple installation configurations, either one
can be used to power the control.
DO NOT plug 2 separate power supplies in these ports.