Operating Instructions EMAX designs and manufactures products for safe operation. However, operators and maintenance persons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation. Keep these instructions for reference. Silent Air Portable Air Compressor Model # : HP15P004SS UPC: 815002013954 EMAX Compressor 1000 Cass Dr., Clayton, OH 45315 USA 866.294.
HULK Power Air Compressors Contents Model Specifications…………………………… 2 Installing the air filter …………………… 8 Description………………………………………… 3 Operation …………………………………………… 8 Get to know your compressor…………… 3 Before operating your new air compressor: …………………………………… 8 Safety Information……………………………… 4 General Overview………………………………… 9 Basic Guidelines………………………………… 4 Installation and Location………………… 9 Breathable Air………………………………… 5 Connecting to Power Source…………… 9 Pressurized Components………………… 5 Extension
Silent Air Series Description 9 5 11 8 6 10 fig 1 3 1 2 3 properly. 5.RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compressed air built up in the tank. 6.PRESSURE SWITCH Controlled by the red tipped power switch lever which turns the air compressor on and off. When switch lever is pulled up, compressor is turned off.
HULK Power Air Compressors Notice indicates important information, that if not followed, may cause damage to equipment. 7. AIR FILTER Ensures the air being pressurized is free of contaminants and reduces the amount of noise the pump generates. 7 fig 2 4 6 8.OUTPUT AIR PRESSURE GAUGE Shows the pressure of the air as it leaves the compressor. 9.HANDLE Convenient, rubber gripped handle allows for easy transport of your air compressor. 10.AIR REGULATOR The air regulator controls the output air pressure.
Silent Air Series 4. NEVER modify the compressor and/or controls in any way. personal protective equipment. This includes respiratory protective equipment, protection for the extremities, protective clothing, protective shields and barriers, electrical protective equipment, and personal hearing protective equipment. 5. Keep a first aid kit in a convenient place. Seek medical assistance promptly in case of injury. Avoid infection by caring for any small cuts and burns promptly. 1.
HULK Power Air Compressors condensation dripping on compressor which could cause rust and/or motor shorting. 13. Always disconnect the tool from power source before making any adjustments, storing, servicing, or changing accessories. Such preventative safety measures reduce the risk of starting the tool accidentally. Electrical Safety Be sure only trained and authorized personnel maintain this compressor in accordance with all applicable federal, state and local codes, standards and regulations.
Silent Air Series air tools, air hoses, pipes, valves, filters and other fittings accordingly. DO NOT exceed manufacturer’s rated safe operating pressures for these items. Keep all persons away from the discharge opening of hoses or tools or other points of compressed air discharge. If the machine is installed in an enclosed area, be sure to vent the relief valve outside of the structure or to an unoccupied area. 2.
HULK Power Air Compressors Total Extension Cord Length Amp Rating Feet Meters Feet Meters Feet Meters Feet Meters 25 8 50 15 100 30 125 40 3-10 amp 18 ga. 16 ga. 14 ga. 14 ga. 10.1 - 12 amp 16 ga. 16 ga. 14 ga. 14 ga. 12.1 - 16 amp 14 ga. 12 ga. Not Recommended Use only UL or CSA approved extension cords Power Source Connection 120 Volts, 60 Hz, single phase, 15 amp power source.
Silent Air Series center inspect and test the air compressor to ensure that is working properly. ●● Pull the ring on the safety valve before each use to make sure the valve is functional. ●● Depending on the CFM draw of the tools being operated, your new air compressor can be used for operating paint sprayers, air tools, grease guns, airbrushes, caulking guns, abrasive blasters, tire & plastic toy inflation, spraying weed killer and insecticides, etc.
HULK Power Air Compressors 3. If not draining the tank, reduce tank pressure through the air hose. 4. Drain the tank by slowly opening the drain valve (fig 6.1). Place a catch basin under the valve to protect the surface from water damage. Pressure Switch 2. Check that the pressure switch is moved clockwise to the OFF position (fig 7.0). Cold Weather Starting 4. Insert the power supply cord into the power supply socket.
Silent Air Series Troubleshooting Always inspect the compressor before use, and make sure it is in good working condition. Make sure all air vents are clear. Check the power cable to make sure it is intact and free from cracks, bare wires etc. Avoid using solvents when cleaning plastic parts, most plastics are susceptible to damage from the various types of commercial solvents. Trouble Compressor will not start Possible Cause Corrective Action 1. Blown fuse or circuit breaker tripped 1.
HULK Power Air Compressors Parts List No. Description 1 Fan screw 2 3 No.
Silent Air Series Schematic Drawing 13 HP15P004SS man v.
HULK Power Air Compressors Warranty Statement HULK makes every effort to ensure that this product meets high quality and durability standards. HULK warrants to the original retail consumer a 2-year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials. Warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence or accidents, repairs or alterations and lack of maintenance.