Operating Instructions EMAX designs and manufactures products for safe operation. However, operators and maintenance persons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation. Keep these instructions for reference. Silent Air Portable Air Compressor Model # : HP02P010SS UPC: 815002014005 EMAX Compressor 1000 Cass Dr., Clayton, OH 45315 USA 866.294.
HULK Power Air Compressors Contents Model Specifications…………………………… 2 Installing the air filter …………………… 8 Description………………………………………… 3 Operation …………………………………………… 8 Get to know your compressor…………… 3 Before operating your new air compressor: …………………………………… 8 Safety Information……………………………… 4 General Overview………………………………… 9 Basic Guidelines………………………………… 5 Installation and Location………………… 9 Breathable Air………………………………… 5 Connecting to Power Source…………… 9 Pressurized Components………………… 5 Extension
Silent Air Series Description 7 7 9 12 12 fig 1 2 1 3 properly. 5.RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compressed air built up in the tank. 6.PRESSURE SWITCH Controlled by the red-tipped power switch lever which turns the air compressor on and off. When switch lever is pulled up, compressor is turned off. When lever is moved down to the "Auto" position, the pressure switch is engaged and will start the compressor pump automatically when tank pressure is below the factory-set minimum.
HULK Power Air Compressors Safety Information 7. AIR FILTER Ensures the air being pressurized is free of This manual contains very important information to know and understand. This is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help understand this information, observe the following: Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Silent Air Series Basic Guidelines 5. If the air tank develops a leak, replace it immediately. Never repair, weld or make modifications to the air tank or its attachments. 1. Allow only trained, authorized persons who have read and understood these operating instructions to use this compressor. Failure to follow the instructions, procedures and safety precautions in this manual can result in accidents and injuries. 2. NEVER start or operate the compressor under unsafe conditions.
HULK Power Air Compressors 3. Use shims to level compressor if installation area is not flat. This will avoid excessive vibration and premature pump wear. refrigerators. There is an increased risk of electric shock if your body is grounded. 11. To reduce the risk of electrical shock or injury, do not expose tool to moisture. Don’t use this tool in damp or wet locations. Keep out of rain. DO NOT install compressor in boiler room, paint spray room, or area where sandblasting occurs.
Silent Air Series icer systems with antifreeze compound, shut off compressor and allow it to cool. Keep sparks, flames and other ignition sources away and DO NOT permit smoking in the vicinity. 9. Stop compressor and disconnect power if a hazardous condition arises. 20. Compressed air from the unit may contain carbon monoxide. Air produced is not suitable for breathing purposes. 21. Always use a respirator when spraying paint or chemicals. Air Tool Cautions 1.
HULK Power Air Compressors Total Extension Cord Length Amp Rating Feet Meters Feet Meters Feet Meters Feet Meters 25 8 50 15 100 30 125 40 3-10 amp 18 ga. 16 ga. 14 ga. 14 ga. 10.1 - 12 amp 16 ga. 16 ga. 14 ga. 14 ga. 12.1 - 16 amp 14 ga. 12 ga. Not Recommended Use only UL or CSA approved extension cords Power Source Connection 120 Volts, 60 Hz, single phase, 15 amp power source.
Silent Air Series ●● Depending on the CFM draw of the tools being operated, your new air compressor can be used for operating paint sprayers, air tools, grease guns, airbrushes, caulking guns, abrasive blasters, tire & plastic toy inflation, spraying weed killer and insecticides, etc. Proper adjustment of the air pressure regulator is necessary for all of these operations. Refer to the air pressure specifications provided with the tool you are using.
HULK Power Air Compressors 5. Turn the pressure switch on, moving the lever to the AUTO position (fig 8.1). 0 1 OFF AUTO fig 8 6. On the reservoir pressure gauge, you can watch pressure build in the tank until the pump stops at the factory-set pressure, about 115 to 125 psi. 7. This first time running your compressor and periodically thereafter, check for air leaks.
Silent Air Series Troubleshooting Always inspect the compressor before use, and make sure it is in good working condition. Make sure all air vents are clear. Check the power cable to make sure it is intact and free from cracks, bare wires etc. Avoid using solvents when cleaning plastic parts, most plastics are susceptible to damage from the various types of commercial solvents. Trouble Compressor will not start Possible Cause Corrective Action 1. Blown fuse or circuit breaker tripped 1.
HULK Power Air Compressors Parts List No. Description Qty. No. Description Qty.
Silent Air Series Schematic Drawing 75 40 40 74 13 HP02P010SS man v.
HULK Power Air Compressors Warranty Statement HULK makes every effort to ensure that this product meets high quality and durability standards. HULK warrants to the original retail consumer a 2-year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials. Warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence or accidents, repairs or alterations and lack of maintenance.