Use and Care Manual
4
HULK Power Air Compressors
4
o. When lever is moved down to the "Auto"
position, the pressure switch is engaged and will
start the compressor pump automatically when
tank pressure is below the factory-set minimum.
The pressure switch continues to monitor the
pressure and turns the pump o when the
pressure reaches the factory-set maximum.
Always make sure that the
compressor power switch is in
the OFF position before performing any
maintenance or plugging the compressor into a
power supply.
7. AIR FILTER -
Ensures the air being pressurized is free of
contaminants and reduces the amount of noise
the pump generates.
8. OUTPUT AIR PRESSURE GAUGE -
Shows the pressure of the air as it leaves the
compressor.
9. HANDLE -
Convenient, rubber gripped handle allows for
easy transport of your air compressor.
10. AIR REGULATOR -
The air regulator controls the output air
pressure. Turn regulator clockwise to increase
air pressure, counter-clockwise to decrease air
pressure.
11. AIR COUPLER -
Convenient brass quick-disconnect air coupler
allows for fast easy connection to an air hose.
12. WHEELS-
fig 2
5
4
6
8
10
Safety Information
This manual contains very important information to
know and understand. This is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS. To help
understand this information, observe the following:
Danger indicates an imminently
hazardous situation which, if not
avoided, will result in death or serious injury.
Warning indicates a potentially
hazardous situation which, if not
avoided, could result in death or serious injury.
Caution indicates a potentially
hazardous situation which, if not
avoided, may result in minor or moderate injury.
Notice indicates important
information, that if not followed,
may cause damage to equipment.
Read all manuals included with this
product carefully. Be thoroughly
familiar with the controls and the
proper use of the equipment.
CALIFORNIA PROPOSITION 65
This product or its power cord
may contain chemicals known to
the State of California to cause cancer and birth
defects or other reproductive harm. Wash hands
after handling.
MANUAL