Use and Care Manual
9
HP01P002SS man v.170726
Silent Air Series
Use only air hoses rated for use
with 115 psi air pressure or
higher.
To install an air hose equipped with a 1/4" male
connector (g 3):
1. Simply push the "connector" or "plug" into the
tting (g 4) and it automatically engages.
2. Verify that air hose is securely connected to air
coupler by pulling on the air hose.
Drain Valve
1. Make sure the drainage valve is closed (g
5.0) and not in the open position (g 5.1).
fig 3
fig 4
0
1
0
1
fig 5
Pressure Switch
2. Check that the pressure switch is pointed up,
in the OFF position (g 6.0).
3. Ensure that the power supply you are going to
use is operating normally.
4. Insert the power supply cord into the power
supply socket.
5. Turn the pressure switch on, moving the lever
to the AUTO position (g 6.1).
6. On the reservoir pressure gauge, you can
watch pressure build in the tank until the pump
stops at the factory-set pressure, about 115 to
120 psi.
7. This rst time running your compressor and
periodically thereafter, check for air leaks. If
the gauge indicates pressure is going down in
the tank or you hear leakage, you could apply
soapy water to all joints in the air transport
piping. Tighten these joints if bubbles form.
1
AUTO
0