Installation Instructions
Table Of Contents
- Title page
- Contents
- About this manual
- Safety information
- Ch 1 - Introduction
- Ch 2 - Adding cards to the Controller
- Unpacking the System Controller
- Unpacking the picocells
- System Controller card configuration
- Adding cards to the System Controller (first steps)
- Jumper and DIP switch settings
- Attaching bus cables
- Adding cards to the System Controller (final steps)
- Configuring Controller cards
- Verifying the card configuration
- Ch 3 - Installing the Controller
- Ch 4 - Verifying the Controller configuration
- Ch 5 - Configuring the router
- Ch 6 - Testing picocells
- Ch 7 - Installing picocells
- Ch 8 - Connecting to external equipment
- Ch 9 - System testing
- Ch 10 - Installation inspection
- Ch 11 - Provisioning
- Ch 12 - Remote Client
- Ch 13 - Troubleshooting
- Ch 14 - Maintaining Quad T1 cards
- App A - Specifications
- App B - Standards compliance information
- App C - Part numbers
- App D - Updates and backups
- Index
1026209–0001 Revision B
Equipment specifications A–3
The environmental specifications for the System Controller are
consistent with indoor commercial electronic communication products.
Table A-1 System Controller environmental specifications
Preliminary specifications – subject to change
Operational Non–operational
(unpackaged)
Non–operational (packaged)
Temperature
+5_C to +50_C
Temperature gradient of up
to 20_C per hour within the
operational temperature
range
–40_C to +60_C
Humidity
5% – 85% relative humidity
over the operational
temperature range
Up to 95% relative humidity
over the non–operational
temperature range
Vibration
0.21 g rms of random
vibration
Frequency PSD
(Hz) (g
2
/Hz)
5–350 0.0001
350–500*
500 0.00005
* Slope: –6 dB/Oct
2.09 g rms of random
vibration
Frequency PSD
(Hz) (g
2
/Hz)
5–100 0.0150
100–137*
137–350 0.0080
350–500*
500 0.0039
* Slope: –6 dB/Oct
The vibration limits for
transport in a turbo
propeller aircraft (3g peak
acceleration from 50 to 500
Hz) apply. The System
Controller was tested on all
three axes, 10 minutes per
axis.
Swept sine:
Freq. g Force Sweep Rate
(Hz) (g) octave/min
5–50 0.5 0.1
50–500 3.0 0.25
Resonant dwell: the System
Controller will not be damaged
as a result of a 0.5 g (0 to
peak) resonant search, from 5
Hz to 200 Hz at a sweep rate
of 1 octave per minute,
followed by a 5 minute dwell
at package resonance.
Random:
Frequency PSD
(Hz) (g
2
/Hz)
5–100 0.0150
100–200*
200 0.0039
* Slope: –6 dB/Oct
Environmental