Installation Manual
Table Of Contents
1027144–0001 Draft – Revision D.01 3–28 Installing indoor RT equipment
RT installation
Service–specific interface modules (SSIs) provide interfaces to
support specific network services. SSI types used depend on the
needs of the customer network.
The following SSIs can be installed in the RT IDU chassis:
• Quad–DS1 (HNS 1027070–0001)
• DS3–TDM (HNS 1027094–0001)
• Universal–DS1 (HNS 3003132–0001)
• DS3–ATM (HNS 3003136–0002)
• DS3–Transparent (HNS 1027094–0002)
The following RT SSIs are currently in development:
• MPEG
• Ethernet 10BaseT/100BaseT
SSIs are installed in slots 2 through 5 in the RT IDU chassis.
The Quad–DS1 SSI, shown in figure 3-15, provides up to a four
T1 or E1 line link between the HT and RT.
Figure 3-15 Quad–DS1 SSI
QUAD DS1-SSI
OK
PORT 1
STATUS
rt004
LEDs indicate
SSI status
RJ-48X connectors
PORT 2 PORT 3 PORT 4
ALARM
The maximum cable length for a Quad–DS1 SSI is 655 feet
(199.6 meters).
The pinouts for the RJ–48X connectors on the Quad–DS1 SSI are
shown in figure 3-16.
3.5
SSIs
Quad–DS1