User's Manual

10271450001 Revision D 6–40 Installing indoor hub equipment Hub installation
Check the status of the installed SSIs as follows:
(Note that SSIs are not required for commissioning. They can be
installed after HT commissioning.)
1. Press Enter on the CCM front panel while the Initializing
screen shown below is displayed:
Initializing
Press Enter for Menu
(This screen is displayed
only after powerup or
reset, after SUDS.)
This puts the IDU into diagnostic mode. The LCD shows
the Main Menu:
Main Menu
Status
2. Press Enter, to go to (select) the Status menu:
Status
CCM
3. Press the up arrow button to scroll to the SSI Status menu:
Status
SSI 2
4. Use the arrow button(s) to scroll to the SSI you want to
check:
Status
SSI 3
Note: SSIs are numbered SSI 1 through SSI 4, according to
their positions in the IDU chassis:
Chassis slot SSI number
2 1
3 2
4 3
5 4
Slot 1 is occupied by the CCM.
Check SSI status