1027144–0001 Revision D 9–4 Troubleshooting RT installation
1. Select Install from the LCD Main Menu.
2. Point the RT antenna in the direction of the
HT.
3. Enter the RT serial number in the EMS
database.
4. Make sure the RT ODU frequency is selected
via the LCD Freq function.
5. Check IFL cable for continuity, and check IFL
connectors.
6. Replace CCM.
7. Replace ODU.
Cannot find the HT.
Problem:
rt068
Troubleshooting: RT antenna pointing
1. Read voltage on voltmeter; refer to table
2. Move the antenna in azimuth. If the voltage
does not vary as you move the antenna, the
CCM may be faulty. Continue with the steps
below.
3. Check
the ODU frequency via the LCD Freq function.
Power the CCM off and then on (by removing it
and then reinserting it); then make sure the ODU
frequency is still correct.
4. Replace CCM.
Select Install from the LCD Main Menu.
Yes
No
Can you detect
voltage at the
ODU pointing
connector?
7-1 .