1027145–0001 Revision E 6–2 Installing indoor hub equipment Hub installation
The optional hub rack (figure 6-1) provides a location for
mounting:
• IDUs (8 maximum)
• A dc power distribution unit
• The hub LAN router
Figure 6-1 Optional hub rack
hb076
Capacity:
8 IDUs (allowing for power distribution
unit and space for cabling)
Base (insulator plate):
16 by 20 inches
(40.6 by 51.4 centimeters)
¼
Height:
7 feet
(2.1 meters)
Mounting holes:
18-5/16 inches
(approximately
46.4 centimeters)
Overall:
20-5/16 inches
(approximately
51.5 centimeters)
Rack width
Follow these instructions to install the hub rack—if the hub plans
call for a rack or racks:
1. Refer to the hub plans and drawings to determine where the
rack should be installed.
6.1
Installing the hub
rack (optional)