1027145–0001 Revision E 5–10 Installing IFL cables
Hub installation
2. Route the cable from the IDU chassis location through the
base of the lightning arrestor and the restraining fitting, as
shown in figure 5-6.
Figure 5-6 Routing IFL cable
T0006028
From
IDU
Restraining
fitting
Terminate with
N connector
here.
3. Terminate the end of the IFL cable with an N connector.
For detailed instructions for connecting an N connector, see
appendix C.
4. Connect the cable to the RF arrestor, as shown in figure 5-7.
5. Working from inside the arrestor body, use a wrench to
tighten the restraining fitting.
6. If you are installing additional IFL cables, repeat steps 1
through 5
hb080
RF arrestor
Figure 5-7 Connecting the IFL cable to the RF arrestor