Appendix C
Terminating IFL cables
This appendix explains in detail how to terminate the IFL cable
ends by attaching an Ntype connector. It includes:
Cable parts and terminology page C–2
Preparing the cable end page C–3
Attaching the connector page C–6
Applying heatshrink tubing page C11
As part of the RT installation, you attach N connectors in four
locations, as shown in figure 5-1 (on page 5–3):
One N connector at the IDU location
Two N connectors to connect to the lightning arrestor
assembly
One N connector at the ODU location
Important: Sound IFL cable connections are critical for
proper operation of the AIReach Broadband system.
Therefore, be very careful in terminating the cable. If you are
unsure about the success of any of the following steps, repeat
them.
Attach N connectors after you route and install the cable, not
before.
Note: The instructions below are for the connectors in HNS kit
9006284–0002. If you use a different Ntype connector, follow the
manufacturers instructions.