1027145–0001 Revision E 6–30 Installing indoor hub equipment Hub installation
Follow these steps to install SSIs:
CAUTION
To maintain proper airflow and protect
against RF interference, keep any empty
chassis slots covered with blank panels.
1. If a blank panel is installed in the slot where you will install
the SSI, loosen the thumbscrews on the blank panel and
remove it.
Keep the blank panel for future use.
CAUTION
Always wear a new or recently tested
electrostatic discharge (ESD) wrist strap
(figure 6-20) when handling circuit
modules. Failure to use a wrist strap may
result in damage to components.
TM
BROADBAND
ENTER
PREVNEXT
T0009051
Wrist
strap
Connect to
IDU chassis
ground terminal.
Figure 6-20 ESD wrist strap
Installing SSIs