User Manual

8
Controller Over-current Cut Settings
Current Set represents controller over-current cut settings. The current value can be
changed from 7.0A to 25.0A.
To change basic settings, press the “+” or the “-” button to increase or decrease the
value of the current.
To store a changed setting, press the ON/OFF button. The screen says “OK” and
returns to previous menu.
Current Settings Interface
Power assist Sensor Settings
Assistant num represents the numbers of magnets on PAS disk. The default
number is 12. The adjustable range is 5 to 24.
To change the number of magnets on PAS disk, press UP or DOWN button to
choose the desired quantity.
To store a changed setting, press the ON/OFF button. The screen says “OK” and
returns to previous menu.
The PAS Magnet Quantity Settings
Speed Sensor Settings
SSpeed Sensor represents speed sensor settings. The default value is 1.
To change speed sensor settings, press the UP or the DOWN button to select the
quantity of magnets on the bike spokes (the range is from 1 to 15).
To store a changed setting, press the ON/OFF button. The screen says “OK” and
returns to previous menu.