Owners manual

To allow the 220V GFCI to function properly, connect the white Neutral
wire from the spa to the Neutral terminal on the GFCI breaker, not the Neutral
bus in the GFCI breaker box. An improperly connected Neutral causes the
GFCI breaker to trip.
Wiring the Spa Controls
A green colored terminal is provided in the control box. To reduce the risk of
electrical shock, connect this terminal or connector to the grounding terminal of
your electrical service or supply panel with a continuous green insulated copper
wire.
A second pressure wire connector is provided on the surface of the control box
for bonding to local ground points. To reduce the risk of electrical shock, this
connector should be bonded with copper wire to any reinforced concrete, metal
water pipes, or any metal within 5 feet (1.5m) of the spa. International customers
should contact their HOME & GARDEN SPAS dealer for Electrical Wiring
Requirements.
Refer to supplied wiring diagrams inside the control box for model specic
diagrams and call technical support associate for assistance prior to wiring the
controls for assistance if necessary. Factory trained technical service specialists
are available to answer questions by calling (877) 722-4097 during their normal
business hours Monday through Friday from 8:30 am to 5 PM est.
Do not replace the exterior cabinet panel until your new Home &
Garden Spa has been lled with water and you are sure it it operating
properly. Be sure to hand tighten the unions in the plumbing lines and
Electrical Information
Spa Controls
Black
(HOT)
White
(Neutral)
Red
(Hot)
Green
(Ground)
From GFCI
Ground Terminal Block
(Attached to outside of
Spa Control Box)
17