Owners manual
NFPA/70 and in compliance with Underwriters Laboratories, Inc.. is might be
used as a shut o switch, which must be installed so that it is accessible to the spa
occupants, but not within 5 feet (1.5m) of the spa.
A
ONLY. Do not use aluminum wire. Connection wires, circuit breakers,
and/or fuses, must all be sized to accommodate the Total Ampere load.
110 V INSTALLATION
All 110 volt HOME & GARDEN SPAS are delivered with a GFCI power cord that
is approximately 15 feet in length. Electrical service must be no farther than 15
feet (4.5m) and no closer than 5 feet (1.5m) to the spa. ere is a reset switch
on the power cord which allows you to reset power by pressing the reset button
on the plug. If service is interrupted, you must press the reset button to restore
service.
e dedicated circuit must have a 20 amp GFCI in the main breaker panel
with ground wire and the correct polarity throughout the circuit. A pressure
wire connector is provided on the exterior surface of the control box, inside the
spa. is wire allows grounding between this point and any metal equipment,
reinforced concrete, metal pipe or water pipes within 5 feet (1.5m) of the spa.
e bonding wire must be solid copper wire.
Do not connect the spa using extension cords or surge protectors. e spa
must be connected to a dedicated 110v/20a GFCI protected, grounded circuit.
is circuit must not be used by or shared with any other electrical component.
If it is connected to a shared circuit, it will overload the circuit leading to tripping
at the main breaker.
Power supplied to your Home & Garden Spa must be a through dedicated
circuit with no other appliances, lighting, or any other electronic components
powered by this circuit. Failure to connect the spa to a breaker that is dedicated
may result in damage or failure of the equipment which is not covered by the
manufacturer’s warranty.
Do not use the spa if the cord or plug is damaged. Disconnect the spa from the
power source and do not use until they have been replaced.
Do not apply power to the spa until it has been lled with water.
Electrical Information