Owners manual

AVOID THE RISK OF ELECTROCUTION.
A       
      
N E C (NEC)     
         .
Connecting the spa to an improperly wired circuit will eliminate many of the
spas built in safety features which may result in re, electrocution, or other risk
of injury. Damages to the spa which are the result of improper wiring are not
covered under the manufacturers warranty and will terminate all listings from
independent listing agencies. e electrical diagrams contained in this manual
are included as a guideline for the licensed electrician installing the electrical
connections and may vary by model. Please refer to the diagram in the spa
control box.. All wiring connections must be watertight.
N            
  DO NOT Connect power to the empty spa. Power to the spa
automatically activates critical components within the spa, such as the
controls and the heating. If power is supplied to the components prior to the
spa being lled, the components will be damaged. Damage that occurs to the
components because power was supplied before the spa was lled with water is
not covered by the manufacturer’s warranty.
P       H  G
S,  OFF      
     . Your 220V Home
& Garden Spa must be permanently connected (hard wired) to the power
supply. No plug in connections, extension cords or surge protectors are to be
used in conjunction with the operation of your new spa. Power supplied to
your Home & Garden Spa must be a dedicated circuit with no other appliances,
lighting, or any other electronic components powered by this circuit.
T         
        
  G F C I between the
main service entrance and the spa to open all ungrounded supply conductors
in compliance with Section 422-20 of the National Electrical Code/USA, ANSI/
Electrical Information
14