Spec Sheet
Baffle
JFR
Model JFR
Sizing Information
Model Number Configurator
Food Rethermalizing Requirements
Warranty:
All Hubbell Model JFR booster heaters are backed by a full 1 year parts/labor warranty and additional 4 year tank warranty.
For a Food Rethermalizer:
Minimum of 2000 watts per square foot
(2.2 watts per square cm) of vessel top.
For a Bain-Marie or Steam Table:
Minimum of 750 watts per square foot (0.8 watts per square cm)
of vessel top. Units over 6' long require a minimum of two JFR heaters.
Baffle Information:
The JFR must be installed with a perforated water baffle.
This baffle is not supplied with the heater.
The JFR should be positioned with no more than 3' (91.4 cm)
on either side when mounted in the holding vessel.
Note: Product failure caused by liming or sediment buildup is
not covered under warranty.
Water Quality Requirements:
Incoming water in excess of 3.0 grains of hardness per gallon (GPG)
(.75 grains of hardness per liter) must be treated and softened before
being supplied to hot water dispenser(s). Water containing over
3.0 GPG (.75 GPL) will decrease efficiency and reduce the longevity
of the heater.
Options:
Security Package (Includes Torx
®
screws and digital display cover)
Example:
JFR - 3R
3 kW, 208 Volt, 3 Phase
JFR -
Step 1
kW
3
4
6
9
Step 2
Voltage-Phase:
1Φ Voltages
RS = 208 - 1
S = 240 - 1
W = 277 - 1
T4S = 480 - 1
3Φ Voltages
R = 208 - 3
T = 240 - 3
T3 = 380 - 3
T7 = 415 - 3
T4 = 480 - 3
T6 = 600 - 3
Notes:
• All three phase JFR models are designed with balanced loads.
• The Hubbell JFR is suitable for cold or pre-heated water use.
NSF Standard 4 requires, for products manufactured for the purpose of rethermalizing food, that the food reach a safe serving temperature of
165°F in two hours or less in order to be listed to the NSF4 standard. The Hubbell model JFR is designed specifically for food rethermalizing, but
only in conjunction with a hot water bath rethermalizer. Hubbell supplies neither the vessel nor the system that determines how food is placed and
held in the vessel. The Hubbell JFR only supplies hot water to the vessel. Each vessel must pass its own NSF performance requirements and
although Hubbell provides sizing recommendations to help correctly size the JFR to the vessel, there are many variables involved in the
manufacturing of the vessel that impact its ability to pass the NSF requirements. The Hubbell JFR is ETL and ETL Sanitation (ANSI NSF 4) listed
for construction only. It is the responsibility of the manufacturer of the vessel to have the complete rethermalizing product tested and listed to the
NSF 4 Standard once the JFR is installed onto the vessel.