Cut Sheet
KILLARK LIGHTING
H
A
Z
L
O
C
H
A
Z
L
O
C
L
I
G
H
T
I
N
G
L
I
G
H
T
I
N
G
SEE WWW.HUBBELL-KILLARK.COM LIGHTING SOFTWARE FOR LATEST LED PHOTOMETRY
L55
KF1L SERIES
C1D1 FLOOD – INTRODUCTION & LOGIC
KF1L with KFS-6
Sliptter mount
on 2” pipe
Dark Sky Visor
KF1L-DARK
LED Flood Features and Standards
Supplemental 20KA/10KV Surge Protection
is standard (for 120-277 VAC models)
10KA/10KV Surge Protection (for 347-480 VAC)
• Factory Sealed Construction
• One 3/4” NPT & one M20 entry standard
(see logic for other choices)
• Crisp White Light for Excellent Color
Rendering – Chromaticity 5000 K (CCT);
approx. 70 CRI
• Energy Savings – High lumens per watt
• LED Array Life – 100,000+ hours with 70%
initial lumens
• Long Fixture Life – 50,000 - 55,000
maintenance free hours
• Instant On – Including after power
interruption
• World Voltage 120 – 277VAC 50/60Hz
• Solder-LESS LED Board Connections –
Vibration Resistant
Class I, Div. 1&2, Groups B,C,D
Class I, Zone 1&2, Groups IIB+H2, IIA
Class II, Div. 1&2, Groups EFG, Class III
Enclosure Type 4X, IP66 (-50°C to +55°C)
IEC Ex Rated model (w/IEX or IEX4B suffix) Zone 1,
Zone 21
Ex de IIB+H2 T6..T5, Gb, IP66
Tamb -20°C ≤Ta≤ +55°C; Option LT for -50°C ≤Ta≤
+55°Cj
Ex de IIB T6..T5, Gb, -50°C ≤Ta≤ +55°Cj
Ex tb IIIC T90°C Db, -50°C ≤Ta≤ +55°Cj
IECEx Certificate
CSA 14.0010
ATEX Certificate
SIRA14ATEX1159X
Applications
LED KF1L Series Explosion-proof Floods are
designed for installations where moisture,
dirt, dust, corrosion and vibration may
be present, or Type 3 and 4X areas where
wind, water, snow or high ambients can be
expected. They can be used in locations
made hazardous by the presence of
flammable vapors or gases or combustible
dusts as defined by the NEC/CEC/IECEx/
ATEX & INMETRO
Typical applications include manufacturing
plants, and certain chemical and
petrochemical processing facilities, sewage
treatment plants, off-shore and dockside
installations, garages and storage facilities
Compliances
• UL-8750 for LED lighting
• ANSI/UL 1598A
• UL-844 Standard for lighting fixtures for
hazardous locations, Class I, Division 1;
Class II, Division 1; Class III
• CSA C22.2 no. 137-M1981 electric
luminairies for use in hazardous locations
• Zone 1 and Zone 21 to IEC 60079-0,60079-
1,60079-31, 60079-7 Standards
• Enclosed and gasketed
• Type 3, 4X
• IP66
Materials
• Body, end caps and lens frame corrosion
resistant copper-free aluminum alloy with
baked powder epoxy/polyester finish,
electrostatically applied for complete,
uniform corrosion protection
• All external hardware - stainless steel
• Thermal shock and impact resistant extra
heavy-duty glass lens
• High temperature silicone gasketing
• Trunnion heavy gauge 316 SS
Patent Pending
Fixture
Design
LED
Catalog Number Logic
KF1L 125 30 XX
KF1L - Series Constant
Fixture Wattage
090
- 90W
105
- 105W
110
- 110W
125
- 125W
Voltage
30
- 120 - 277VAC 50/60Hz
33
- 347 - 480VAC 60Hz (90W-125W)
34
- 120-250VDC (90W-125W)
Options
IEX4B -
Four bolt termination cover
LT -
For -50°C to +55°C, IEC Zone 1
F -
Single Fuse (Not for use in Canada)
FF -
Double Fuse (Not for use in Canada)
D20 -
Dual M-20 Entries
D25 -
Dual M-25 Entries
D75 -
Dual 3/4” NPT
Construction/Certification Notes:
KF1L units are standard with
one 3/4” NPT hub & one M20
hub – both plugged, with an
8-bolt factory sealed termination
chamber, suitable for CID1 BCD
-50°C to +55°C and IEC Zone 1
Ex de suitable for -20°C to 55°C.
Use option LT for models
needing IEC Zone 1, -50°C to
+55°C suitability for hydrogen.
Option IEX4B utilizes 4 terminal
cover bolts for Ex de and
maintains all ratings
EXCEPT CID1 BCD.
See logic for other entry options
File LR11713
FEATURES-SPECIFICATIONS
150
- 150W
165
- 165W
195
- 195W
Suitable for Paint
Spray