BTS3701B V300R003 Installation Guide Issue: 01 Date: 2010-03-20 HUAWEI TECHNOLOGIES CO., LTD.
Safety Precautions ■ Abide by All Safety Requirements To ensure personal and equipment safety, abide by safety precautions described in the label on equipment or in the manual when you install, operate, or maintain the equipment. The "Safety Warning", "Caution", and "Note" in the manual are not the contents of safety requirements. They are provided as the supplement to the safety precautions.
Installation Process Tools Measuring tape Vacuum cleaner Diagonal pliers Marker Hammer drill Adjustable wrench Phillips screwdriver Level Ladder Rubber mallet Wire stripper z When an external antenna is used, connect the antenna to the BTS3701B before installing the BTS3701B. z When the BTS3701B is installed on a wall, the integrated mode is recommended. z The BTS3701B must be installed at least 0.
Space Requirements a Dimensions of the BTS3701B 65 mm (2 9/16'') 230 mm (9 1/16'') 165 mm (6 1/2'') b Minimum Space Requirements ≥ 300 mm (11 13/16'') ≥ 250 mm (9 13/16'') ≥ 100 mm (3 15/16'') ≥ 250 mm (9 13/16'') ≥ 170 mm (6 11/16'') A minimum of 500 mm (1'-7 11/16'') should be reserved at the back of the BTS3701B only in the ceiling installation mode.
Installation Modes Adapter BTS3701B Transitional piece Mounting bracket for the module Ceiling mounting bracket Mounting bracket for the adapter a Installing the BTS3701B on a Wall (Separated Mode) Regular installation Reverse installation b Installing the BTS3701B on a Wall (Integrated Mode) Regular installation Reverse installation 4
Installation Modes 20 mm (13/16'') to 65 mm (2 9/16'') The requirements for the installation carrier are as follows: 20 mm (13/16'') to 75 mm (2 15/16'') 20 mm (13/16'') to 85 mm (3 3/8'') Pole 20 mm (13/16'') to 75 mm (2 15/16'') Angle steel 20 mm (13/16'') to 65 mm (2 9/16'') U-steel c Installing the BTS3701B on a Pole (Separated Mode) Regular installation Reverse installation d Installing the BTS3701B on a Pole (Integrated Mode) Regular installation Reverse installation 5
Installation Modes e Installing the BTS3701B on a Ceiling Regular installation Reverse installation If the BTS3701B is installed on a ceiling, the ceiling must be made of concrete and can bear a weight of 323.6 N.m (2864.10 lbf.in.).
Installing the BTS3701B on a Wall c Separated Mode M4 M3.5×20 3 ± 0.5 N.m (26.55 ± 4.43 lbf.in.) Installation procedure The procedures of regular installation and reverse installation are identical.
Installing the BTS3701B on a Wall d Integrated Mode M4 3 ± 0.5 N.m (26.55 ± 4.43 lbf.in.) 10 N.m (88.51 lbf.in.) The procedures of regular installation and reverse installation are identical.
Installing the BTS3701B on a Pole a Separated Mode 3 ± 0.5 N.m (26.55 ± 4.43 lbf.in.) ≥ 300 mm (11 13/16'') M4 b Integrated Mode M4 3 ± 0.5 N.m (26.55 ± 4.43 lbf.in.) 10 N.m (88.51 lbf.in.) The procedures of regular installation and reverse installation are identical.
Installing the BTS3701B on a Ceiling a Determining Installation Positions of Bolts b Drilling Holes and Installing Expansion Bolts 24 mm (15/16'') to 25 mm (1'') Marking template c Installing the BTS3701B on a Ceiling M3.5×20 Installation procedure 10 N.m (88.51 lbf.in.) The procedures of regular installation and reverse installation are identical.
Connecting Cables 4-pin connector of the DC input power cable Cable Connector Connected to... Straightthrough cable RJ45 connector FE/GE port on the BTS3701B RJ45 connector Operator's transmission equipment Power cable PA male connector AC power wiring bar C7 female connector Power adapter DC input power cable 4-pin connector PWR port on the BTS3701B The other end is connected to the power adapter.
Appendix: Cabling Routes for Different Installation Modes a Installing the BTS3701B on a Wall Separated Mode Integrated Mode b Installing the BTS3701B on a Pole Separated Mode c Installing the BTS3701B on a Ceiling Integrated Mode Straight-through cable DC input power cable Power cable z When the BTS3701B is installed on a pole, fix the input power cable of the power adapter on the pole using a tie wrap. z Before powering on the equipment, ensure that the antenna of the BTS3701B is vertical.
e Installing the External Equipment FE/GE POWER Powered device (PD) IN OUT Network equipment OUT The distance between the PSE and the PD should be more than 1 m (3'-3 3/8''). The PSE cannot be installed on a ceiling. IN Power sourcing equipment (PSE) Appendix: Removing the Equipment Spring pad Press the spring pad and rotate the BTS3701B clockwise to remove it.
Huawei Technologies Co., Ltd. Administration Building, Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, P. R Zip code: 518129 www.huawei.