Instruction Manual

Emergency Stop Button
Note: Tip: The manual probe process will automatically set the origin of X, Y, and Z
axes. There is no need to set them again.
Just like the main button in front of the Carvera machine, when any unexpected situation occurs, you
can quickly press the emergency stop button to stop the machine, and the machine will stop immedi-
ately and enter the alarm state. You need to go to the control software to unlock the machine before
continuing to use it. The emergency stop button has a self-locking function, just turn the emergency
stop button clockwise to unlock it.
6. Click OK to start the probing process.
Manual Probe
Use case: Normally, using the wireless probe and the anchor-based positioning system is quite enough
for most jobs. But when you need to place the workpiece not at the anchor point and need to accurately
find the origin, you can use the manual probe.
Usage:
1. Plug the manual probe into the 2-pin socket on the left side of the machine bed.
2. Place the manual probe (white plastic side) against the lower left corner of the workpiece firmly.
3. Move the machine and let the milling bit be positioned in the square area of the manual probe.
4. Attach the magnetic end of the manual probe to the spindle shaft as shown.
5. Click the "XYZ Probe" function, and set the height offset and the diameter of the milling bit. (It is
recommended to use the 3.175mm diameter test rod we provided for probing so that the default
parameters can be applied directly)
42
Tool Kit
43
Tool Kit