Product Brochure
www.htproducts.com • MKTLIT-59 • 05 / 2016 © HTP
In accordance with our company policy of ongoing product improvement, HTP Inc. reserves the right to make changes without prior notice.
Energy Factor based on D.O.E. (Department of Energy) test procedures. Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring.
SPECIFICATIONS AND DIMENSIONS
WATER TEMPERATURE RATINGS
Models Gal. A B C D
Minimum
Delivered Temp.
Maximum
Delivered Temp.
High
Temp. Limit
EVC080C2X045
80 6.5” 60” 69” 23.25”
120°F
48.8
°
C
181°F
82.8
°
C
200°F
93.3
°
C
EVC080C2X055
EVC100C2X045
100 7.25” 52” 61” 27”
EVC100C2X055
EVC115C2X045
115 7.25” 60.25 70.5” 27”
EVC115C2X055
Light Commercial
Models
Wattage Voltage
Safety
Listing
First Hour
Delivery
Recovery @
90
º
F Rise
Thermal
Eciency
Shipping
Weight
EVC080C2X045 4500
240
UL1453
84 Gallons 20 Gallons
98 %
151 lbs
EVC080C2X055 5500 89 Gallons 25 Gallons
EVC100C2X045 4500
240
87 Gallons 20 Gallons
98 %
206 lbs
EVC100C2X055 5500 92 Gallons 25 Gallons
EVC115C2X045 4500
240
105 Gallons 20 Gallons
98 %
224 lbs
EVC115C2X055 5500 110 Gallons 25 Gallons
Specifications
Commercial
The Inlet & Outlet have Built in
Heat Traps, Keeping the Heat in
the Tank for Greater Efciency
45.00°
45.00°
B
RELIEF VALVE
TEMPERATURE/PRESSURE
ELEMENT &
THERMOSTAT
ACCESS
TANK
DRAIN
B
C
A
D
COLD WATER
INLET
HOT WATER
OUTLET
ELECTRICAL
ACCESS PANEL
HOT WATER
OUTLET
COLD WATER
INLET
ELECTRICAL
ACCESS PANEL
RELIEF VALVE
TEMPERATURE/PRESSURE
ELEMENT
&
THERMOSTAT
ACCESS
TANK
DRAIN
C
D
A
45.00°
45.00°
B
RELIEF VALVE
TEMPERATURE/PRESSURE
ELEMENT &
THERMOSTAT
ACCESS
TANK
DRAIN
B
C
A
D
COLD WATER
INLET
HOT WATER
OUTLET
ELECTRICAL
ACCESS PANEL
HOT WATER
OUTLET
COLD WATER
INLET
ELECTRICAL
ACCESS PANEL
RELIEF VALVE
TEMPERATURE/PRESSURE
ELEMENT
&
THERMOSTAT
ACCESS
TANK
DRAIN
C