SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal Protection for Emergency
Situations:
Use the personal protective equipment recommended in Section 8
and a NIOSH approved self-contained breathing apparatus.
Spill Mitigation Procedures
Air Release:
Not applicable
Water Release:
This material is soluble in water. Notify all downstream users of
possible contamination. Divert water flow around spill if possible and
safe to do so.
Land Release:
Create a dike or trench to contain materials. Absorb spill with inert
material (e.g., dry sand, clay, earth or commercial absorbent), then
place in a chemical waste container. After removal, flush
contaminated area thoroughly with water. Avoid runoff into storm
sewers and ditches which lead to waterways.
Additional Spill Information :
Stop source of spill as soon as possible and notify appropriate
personnel. Utilize emergency response personal protection
equipment prior to the start of any response. Evacuate all non-
essential personnel. Dispose of spill residues per guidelines under
Section 13, Disposal Consideration.
SECTION 7. HANDLING AND STORAGE
Handling:
Do not take internally. Avoid contact with skin, eyes and clothing.
Upon contact with skin or eyes, wash off with water.
Storage:
Store in a cool, dry and well ventilated place. Keep containers tightly
closed when not in use.
Incompatible Materials for Storage:
Refer to Section 10, "Incompatible Materials."
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Ventilation:
Use local exhaust ventilation to maintain levels below exposure limits.
Protective Equipment for Routine Use of Product
Respiratory Protection :
Wear a NIOSH approved respirator if levels above the exposure limits are
possible. Wear a NIOSH approved N95 respirator.
Skin Protection :
Avoid contact with skin. Impervious gloves
Eye Protection:
Use safety glasses with side shields.
Protective Clothing Type:
impervious clothing
General Protective
Measures:
Ensure that eyewash stations and safety showers are close to the
workstation location.
Components with workplace control parameters
no data available