User's Manual Industrial Pyrometer Please read this user's manual thoroughly before using this unit and keep it properly for your future reference.
Contents 1. Introduction ................................................................ 1 2. Features ...................................................................... 2 3. Application ................................................................. 3 4. Safety.......................................................................... 3 5. Field of View .............................................................. 4 6. Specifications ............................................................. 5 7.
1. Introduction Congratulations on your purchase of our professional non-contact industrial pyrometer with Type-K input measurement. These units can provide fast, easy and accurate temperature readings. With the non-contact (IR) and contact (TK) technology, they can be used to measure the surface temperature of hard-to-reach objects like electrified equipment or moving objects, without any damage to them.
2. Features ◆ Fast and easy measurement ◆ Precise IR and TK temperature measurement ◆ Built-in round laser pointer increase the target accuracy ◆ Adjustable emissivity: 0.1~1.0 ◆ ºC/ºF selection ◆ MAX, MIN, DIF, AVG record ◆ REC datalogger function for 12 points ◆ LCD display with backlight ◆ Resolution 0.
3. Application These units can be widely used in Food preparation, Safety and Fire inspection, Plastic molding, Asphalt, Marine, Printing ink, dryer temperature and Fleet maintenance. 4. Safety ◆ Use extreme caution when the laser beam is turned on. ◆ Do not point the beam toward human or animal eyes. ◆ Do not allow the beam to strike the eye from a reflective surface. ◆ Do not use the laser near explosive gases.
5. Field of View The meter's field of view is 30:1, for example, if the meter is 30 inches from the target spot, the diameter of the target must be at least 1 inch. Other distance ratios are show as Fig. 1 in the field of view diagram.
6. Specifications IRX-63 IRX-64 IRX-65 IRX-66 IR:-50~850℃ IR:-50~1050℃ IR:-50~1250℃ IR:-50~1550℃ /-58~1472℉ /-58~1922℉ /-58~2282℉ /-58~2822℉ TK:-50~1370℃ TK:-50~1370℃ TK:-50~1370℃ TK:-50~1370℃ /-58~2498℉ /-58~2498℉ /-58~2498℉ /-58~2498℉ Range IR:-50~0℃/-58~32℉:±4℃/7.2℉ IR:0~500℃/32~932℉:±1.5%±2℃/3.6℉ Accuracy Above500℃/932℉: ±2.0%±2℃/3.6℉ TK:-50~1370℃/-58~2498℉:±1.5%±1℃/1.8℉ D:S 30:1 Emissivity Adjustable: 0.10~1.0 Resolution 0.1℃(0.
Storage Temp. -20℃~60℃/-4℉~140℉ Relative Humidity Operating:10~95%RH;Storage:<80%RH Power Supply 9V battery Weight 275g Dimensions(L*W*H) 95*83*192mm Safety “ ” Comply with EMC Notes: ◆Accuracy can be ensured while the temperature is at 18℃~ 28℃(64℉~82℉) and humidity is less than 80 % RH. ◆Field of View: Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it.
7.
8. LCD Display Description ① High/Low alarm indication ② Emissivity Icon ③ Laser Icon ④ Backlit Icon ⑤ Measurement Icon ⑥ Data Hold Icon ⑦ ℃/℉ Icon ⑧ Trigger Lock ⑨ Menu function icon ⑩ Temp. values for the MAX, MIN, DIF,AVG, HAL, LAL.
9. Operating Instruction 9.1 Operating steps: ① Hold the meter by its handle grip and point it toward the surface to be measured. ② Pull and hold the Trigger to turn the meter on, the "SCAN" icon will appear and begin testing. ③ The surface temperature being tested will be displayed on the LCD screen. ④ Release the trigger, the "HOLD" icon will appear, and the reading will be held for several seconds. ⑤ The meter will automatically shut off after 35 seconds.
9.2 Button Function 9.2.1 UP/DOWN button ① In Measurement Mode, press button“ ”to switch the temperature unit ℃ or ℉. ② In REC Mode, press button“ ”to review the latest 12 record readings. 9.2.2 Laser/Backlit button ① In Measurement Mode, press button “ ” to turn on/off laser pointer, ② In Measurement Mode, keep pressing button “ ” to select IR temperature measurement or TK temperature measurement. 9.2.
② After power on the meter, keep pressing button“ " ”icon flashes on the screen, then loose button“ Emissivity Mode, press button“ then keep pressing button“ ” until ”, enter into ” to adjust emissivity value, ” return to the normal measurement mode. (After entering into Emissivity Mode, momentarily press button “ 9.2.4 ” can set the High/Low alarm value ). LOCK Button After power on the meter, lock the unit on for continuous measurement by sliding the switch to right LOCK position.
9.3.Battery Replacement 9.3.1 When the low battery icon“ ” appears, replace the meter's battery. 9.3.2 Open the battery cover, replace the 9V battery and close the cover.
10. Notes 10.1 Work Principle The Industrial Pyrometer is designed for measuring surface temperature of an object. The optical sensor can emit, reflect and transmit energy, which is collected and focused on a detector, then translate it into the temperature reading by electronics and displayed on the LCD screen. The laser is used for aiming the target object only. 10.2 Field of View The object under test should be larger than the spot size calculated by the field of view diagram.
As distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. 10.4 Locating a hot spot To find a hot spot, first aim the thermometer to the outside of target area, then scan across in an up and down motion until the hot spot is located. 10.5 Notice Not recommend for measuring shiny or polished metal surfaces like stainless steel, aluminum, etc. No not make measurement through transparent surface such as glass.
Do not immerse it in water. Do not store it in high temperature or humidity. 10.7 Emissivity Most (90%) organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). 11.
Emissivity Table Substance Thermal Substance emissivity Thermal emissivity Aluminium 0.30 Glass 0.90 to 0.95 Asphalt 0.95 Iron oxides 0.78 to 0.82 Concrete 0.95 Lacquer 0.80 to 0.95 Leather 0.95 Plastic 0.85 to 0.95 Ceramic 0.95 Paper 0.70 to 0.94 Copper 0.50 Sand 0.90 Brick 0.90 Rubber 0.95 Carbon 0.85 Timber 0.94 Fatlute 0.94 Textiles 0.94 Frozen food 0.90 Lead 0.50 Hot food 0.93 Marble 0.94 Ice 0.98 Cloth(black) 0.98 Snow 0.90 Plaster 0.8 0to 0.