User Manual
HT211
EN - 18
Frequency (Autorange)
Range Resolution Accuracy Sensitivity Overload protection
9.999Hz 0.001Hz
(1.0%rdg + 5dgt)
>5Vrms 250VDC/ACrms
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 0.001kHz
Duty cycle (Autorange)
Range Resolution Accuracy Sensitivity Overload protection
0.1%99.9%
0.1%
(1.2%rdg + 3dgt)
>1Vrms 250VDC/ACrms
0.01ms< pulse width <10ms; Frequency range: 10Hz 10kHz
Capacitance (Autorange)
Range Resolution Accuracy Overload protection
40.00nF 0.01nF
(5.0%rdg + 35dgt)
250VDC/ACrms
400.0nF 0.1nF
(3.0%rdg + 5dgt)
4.000F 0.001F
40.00F 0.01F
400.0F 0.1F (4.0%rdg +5dgt)
4000F 1F (5.0%lrdg +5dgt)
Temperature with type K probe
Range Resolution Accuracy (*) Overload protection
-20.0°C ÷ 760.0°C 0.1°C
(3.0%rdg + 5°C)
250VDC/ACrms
-4.0°F ÷ 1400.0°F 0.1°F
(3.0%rdg + 9°F)
(*) Accuracy of only instrument without probe