Owner manual
VEGA78
EN - 112
Energy – Single phase / Three phase systems (@ Cos>0.5 and Vmis>60V, clamp type STD)
Parameter
[Wh, VArh, VAh]
Full Scale
Clamp (FS)
Range
[Wh, VArh, VAh]
Accuracy
Resolution
[Wh, VArh, VAh]
Active Energy
Reactive Energy
Apparent Energy
FS 1A
0.0 999.9
1.000 9.999k
(1.0%rdg+6dgt)
0.1
0.001k
1A< FS 10A
0.000 9.999k
10.00 99.99k
0.001k
0.01k
10A< FS 100A
0.00 99.99k
100.0 999.9k
0.01k
0.1k
100A< FS 3000A
0.0 999.9k
1.000 9.999M
0.1k
0.001M
For STD clamp
Vmis = voltage correspondent to power measurement
FS = Full scale clamp
Power Factor (Cos) – Single phase / Three phase systems
Range Accuracy (°) Resolution (°)
0.200.50
1.0
0.01
0.500.80
0.7
0.801.00
0.6
Voltage / Current harmonics
Range Accuracy(*) Resolution
DC 25
a
(5.0%rdg+5dgt)
0.1V / 0.1A
26
a
33
a
34
a
49
a
(*) Accuracy to add at correspondent TRMS paramters
Frequency
Range Accuracy Resolution
42.569.0Hz (0.2%rdg+1dgt)
0.1Hz