User guide
SOLAR300 - SOLAR300N
EN - 19
5.2.3.1. Multi-MPPT photovoltaic system screen – Single-phase output
When SOLAR300N is in connection with MPP300, the display shows the following
parameters:
DC
PV
AC
PARAMETER CAPTION:
PRp: Performance Ratio (ref. active powers)
Pdc Inverter input DC power
DC
Photovoltaic panel performance
Pac Inverter output AC power
AC
Inverter performance
Pnom Photovoltaic system rated power
If the remote unit SOLAR-02 is connected to the
MPP300, the following values are also available:
Irr Solar irradiation
Tpv Default photovoltaic panel temperature
Tenv Default environmental temperature
When Tenv or Tpv values are displayed in blue, it
means that these values are different from the
default ones, as those measured by SOLAR-02
are not available (see § 5.3.2.4)
Fig. 21: Multi-MPPT photovoltaic system screen – Single-phase output
Pressing the F3 (DC) key displays the following screen:
PARAMETER CAPTION:
Vdcx Inverter input DC voltage
Idcx Inverter input DC current
Pdcx Inverter input DC power
x=1,2,3 according to the number of MPPTs set
Fig. 22: Multi-MPPT photovoltaic system DC screen – Single-phase output
Pressing the F4 (AC) key displays the following screen:
PARAMETER CAPTION:
Vac1 Inverter output phase-neutral AC voltage
Iac1 Inverter output AC phase current
Pac1 Inverter output AC power
Fig. 23: Multi-MPPT photovoltaic system AC screen – Single-phase output