Instruction Manual
I-V400 - SOLAR I-V
EN - 30
18. On SOLAR I-V, press key () to access the second
screen which contains the values of the output DC
parameters of the strings according to the number of DC
inputs set (see § 5.2.1.1). In particular, in this screen:
Vdcx = DC voltage of string x
Idcx = DC current of string x
Pdx = DC power of string x.
We recommend checking that the values of the electrical
parameters (Vdc, Idc, Pdc) are consistent with the system
being measured.
15/05/10 15:34:26
Vdc1 460.1 kW
Vdc2 461.4 V
Vdc3 462.5 A
Idc1 2.25 A
Idc2 2.31 A
Idc3 2.21 A
Pdc1 1.035 kW
Pdc2 1.066 kW
Pdc3 1.024 kW
GO – start rec
Select
MPP
19. On SOLAR I-V, press key () to access the third screen
which contains the values of the electrical parameters on
the AC side of the inverter, consistently with the settings
made in § 5.2.2 (single-phase, three-phase 4 wires). In
particular, in this screen:
Vacxy = AC voltage between Phase and Neutral (if
single-phase) or between Phases x and y (if three-
phase)
Iacx = AC current of phase x
Pacx = AC power of phase x
We recommend checking that the values of the electrical
parameters (Vac, Iac, Pac) are consistent with the system
being measured.
15/05/10 15:34:26
Vac12 401.4 V
Vac23 401.1 V
Vac31 400.1 V
Iac1 4.26 A
Iac2 4.26 A
Iac3 4.27 A
Pac1 987 W
Pac2 986 W
Pac3 985 W
GO – start rec
Select
MPP
Example of a screen for
PV systems with three-
phase output
20. Keeping the three instruments near each other (max
distance approx. 1m), press the GO/STOP key on SOLAR I-
V to start testing. Consequently:
The display of SOLAR I-V shows the message “rec. start
waiting”
The display of SOLAR-02 shows the message “HOLD”
and the time, expressed in seconds, remaining before the
recording is started
On MPP300, the STATUS LED turns on green (not
flashing)
15/05/10 15:34:26
PRp - - -
Irr - - - W/m2
Pnom 3.500 kW
Tc - - - °C
Te - - - °C
Pdc 3.125 kW
Pac 2.960 kW
ndc - - -
nac
0
.
9
5
Rec. running
Select
MPP
21. Upon reaching the instant “00” after pressing the
GO/STOP key, the test is started and the three units are
synchronized with each other. In these conditions:
The display of SOLAR I-V shows the message “rec.
running”
The display of SOLAR-02 shows the message
“Recording…”
On MPP300, the STATUS LED flashes green
15/05/10 15:35:00
PRp - - -
Irr - - - W/m2
Pnom 3.500 kW
Tc - - - °C
Te - - - °C
Pdc 3.125 kW
Pac 2.960 kW
ndc - - -
nac
0
.
9
5
Rec. running
Select
MPP