ENGLISH User’s manual © Copyright HT-ITALIA 2012 Release EN 1.
HT82 Table of contents: 1. SAFETY PRECAUTIONS AND PROCEDURES .......................................................... 2 1.1. Preliminary ............................................................................................................ 2 1.2. During use ............................................................................................................. 2 2. GENERAL DESCRIPTION ........................................................................................... 3 2.1.
HT82 1. SAFETY PRECAUTIONS AND PROCEDURES This meter is in compliance with safety standards EN61557 and EN61010-1 related to electronic measuring instruments. For your own safety and to avoid damaging the instrument follow the procedures described in this instruction manual and read carefully all notes preceded by this symbol . When taking measurements: • Avoid doing that in humid or wet places - make sure that humidity is within the limits indicated in paragraph 6.2.1.
HT82 2. GENERAL DESCRIPTION The instrument HT82 detects the phase sequence. 2.1. INSTRUMENT DESCRIPTION LEGEND: 1. Inputs 2. Display Fig. 1: Instrument description 3. PREPARATION FOR USE 3.1. INITIAL This instrument was checked both mechanically and electrically prior to shipment. All possible cares and precautions were taken to let you receive the instrument in perfect conditions.
HT82 4. OPERATING INSTRUCTIONS 4.1. MEASUREMENT DESCRIPTION CAUTION Do not test or connect to any circuit exceeding the specified overload protection. Do not attempt to measure higher voltages to avoid electrical shocks or damages to the instrument. 1. 2. 3. 4. Connect the test cables by following their numbering. Apply the relevant alligator clips to the free ends of the cables. Connect the alligator clips to the electrical mains.
HT82 6. TECHNICAL SPECIFICATIONS 6.1. TECHNICAL FEATURES 6.1.1. Electrical specifications Input voltage range: Frequency voltage range: Absorbed current (by phase): 40V ÷ 690V AC 15Hz ÷ 400Hz 1mA 6.1.2. Safety The instrument complies to: Insulation: Pollution degree: Overvoltage category: Max height: EN 61010-1 Class 2, Double insulation 2 CAT III 600V 2000m; 6561ft 6.1.3. General data Mechanical characteristics Dimensions: Weight: Protection: 130(L) x 69(W) x 22(H)mm; 5.1x2.7x0.9in Approx. 130g; 4.
HT82 7. SERVICE 7.1. WARRANTY CONDITIONS This instrument is guaranteed against material or production defects, in accordance with our general sales conditions. During the warranty period the manufacturer reserves the right to decide either to repair or replace the product. Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it.