Instruction Manual

HT82
EN - 5
6. TECHNICAL SPECIFICATIONS
6.1. TECHNICAL FEATURES
6.1.1. Electrical specifications
Input voltage range: 40V ÷ 690V AC
Frequency voltage range: 15Hz ÷ 400Hz
Absorbed current (by phase): 1mA
6.1.2. Safety
The instrument complies to: EN 61010-1
Insulation: Class 2, Double insulation
Pollution degree: 2
Overvoltage category: CAT III 600V
Max height: 2000m; 6561ft
6.1.3. General data
Mechanical characteristics
Dimensions: 130(L) x 69(W) x 22(H)mm; 5.1x2.7x0.9in
Weight: Approx. 130g; 4.2ounces
Protection: IP 40
Power supply
From the mains.
Display
Characteristics: Custom with phase sequence and detected
phases indications
6.2. ENVIRONMENT
6.2.1. Environmental conditions
Working temperature: 0° ÷ 40°C; 32° ÷ 104°F
Relative humidity: <80%HR
Storage temperature: ÷ 40°C; 32° ÷ 104°F
Storage humidity: <80%HR
6.2.2. EMC and LVD
This product conforms to the prescriptions of the European directive on low voltage
2006/95/EEC (LVD) and to EMC directive 2004/108/EEC.
6.3. ACCESSORIES
6.3.1. Standard accessories
The package contains:
Instrument HT82.
3 test cables.
3 alligator clips.
User’s manual.
Carrying case.