7. TECHNICAL SPECIFICATIONS
7.1. TECHNICAL CHARACTERISTICS
Voltage Test
Test Range: 60-250V AC
Frequency Range: 40-60 Hz
Test Current: < 200mA
Lamp Test
Voltage with new battery: approx. 3kV / 280kHz
Field strength 150-170 kHz: approx. 100 µV/m
Display: “Test” LED on and acoustic signal
Continuity Test
Dielectrical Strength: 250V AC/DC
Test Range: approx. 0-5 MΩ
Test Current: < 7 µA
Display: “Continuity/Voltage” LED on and acoustic signal
7.2. GENERAL CHARACTERISTICS
Power supply
Internal power supply: 1x9V battery NEDA1604, JIS006P, IEC6F22
Mechanical characteristics
Dimensions (LxWxH): 255 x 60 x 40mm; 10 x 2 x 1in
Weight (battery included): approx 170g; 5 ounces
Safety standards
Compliance with standard: IEC/EN61010-1
Insulation: double insulation
Overvoltage category: CAT II 300V
Max altitude: 2000m (6562ft)
7.3. ENVIRONMENT
7.3.1. Environmental conditions of use
Reference calibration temperature: 23 ± 5°C; (73 ± 41°F)
Operating temperature: 0 ÷ 40°C; (32 ÷ 104°F)
Allowable relative humidity: <70%HR
Storage temperature: -10 ÷ 50°C; (14÷ 122°F)
This instrument satisfies the requirements of Low Voltage Directive 2006/95/EEC
(LVD) and of EMC Directive 2004/108/EEC
7.4. ACCESSORIES
7.4.1. Standard accessories
• Battery (not fitted)
• User manual