6.1.1. Electrical specifications
Conversion: TRMS
Measuring rate: 1.5 times per second
Temperature coefficient: 0.15×(accuracy)/°C (<18°C and >28°C)
NMRR Normal Mode Rejection Ratio: >50dB for DC parameters and 50/60Hz
CMRR Common Mode Rejection Ratio: >100dB from DC up to 60Hz on DCV
>60dB from DC up to 60Hz on ACV
6.1.2. Reference guidelines
Safety: IEC/EN61010-1
Insulation: double insulation
Pollution degree: 2
Measurement category: CAT IV 600V, CAT III 1000V (V//A)
Max height of use: 2000m (6561ft)
6.1.3. General data
Mechanical characteristics
Dimensions (L x W x H): 163 x 88 x 48mm (6.4 x 3.5 x 1.9in)
Weight (including battery): 400g (14 ounces)
Power supply
Battery type: 1x9V battery NEDA1604, JIS006P, IEC6F22
Low battery indication: symbol " " is displayed
Battery life: Approx. 300 hours
Auto power OFF: After 30 minutes of idleness
Fuse: F10A/1000V Bussmann type
Display
Specifications: 4 LCD with max. reading 3999 counts + symbol
decimal point sign and bargraph
Out of range indications: “OL” or “-OL”
6.2. ENVIRONMENT
6.2.1. Environmental conditions
Reference temperature: 23° ± 5°C (73 ± 41°F)
Working temperature: 0° ÷ 30°C (32 ÷ 104°F)
Relative humidity: <80%HR
Storage temperature: -20° ÷ 60°C (-4 ÷ 140°F)
Storage humidity: <80%HR
This product conforms to the prescriptions of the European directive on low voltage
2006/95/EEC (LVD) and to EMC directive 2004/108/EEC.
6.3. ACCESSORIES
6.3.1. Standard accessories
Test leads
User manual
Battery
B80: carrying case
6.3.2. Optional accessories
4413-2: couple of 4mm test leads