Instructions
SOLAR 300
- 172 -
Prüfling = Induktiver Generator
Prüfling = Kapazitive Last
90°
180°
Pact+ = 0
Pfc+ = -1
Pfi+ = -1
Preactc+ = 0
Preacti+ = 0
Pact – = Pact
Pfc – = -1
Pfi – = Pf
Preactc- = 0
Preacti – =
Preact
Pact+ = Pact
Pfc+ = Pf
Pfi+ = -1
Preactc+ = Q
Preacti+ = 0
Pact- = 0
Pfc – = -1
Pfi – = -1
Preactc- = 0
Preacti- = 0
0°
Pact+ = 0
Pfc+ = -1
Pfi+ = -1
Preactc+ = 0
Preacti+ = 0
Pact – = Pact
Pfc – = Pf
Pfi – = -1
Preactc- = Preact
Preacti – = 0
Pact+ = Pact
Pfc+ = -1
Pfi+ = Pf
Preactc+ = 0
Preacti+ = Preact
Pact – = 0
Pfc – = -1
Pfi – = -1
Preactc- = 0
Preacti – = 0
270°
Prüfling = Kapazitiver Generator
Prüfling = Induktive Last
Wobei gilt:
Symbol Beschreibung Bemerkung
Pact+
Wert der Wirkleistung +
Pfc+
Kapazitiver Leistungsfaktor +
Pfi+
Induktiver Leistungsfaktor +
Preactc+
Wert der kapazitiven Blindleistung
+
Preacti+
Wert der induktiven Blindleistung +
Positive Parameter
(Verbraucher)
Pact
-
Wert der Wirkleistung
-
Pfc
-
Kapazitiver Leistungsfaktor
-
Pfi
-
Induktiver Leistungsfaktor
-
Preactc
-
Wert der kapazitiven Blindleistung
-
Preacti
-
Wert der induk
tiven Blindleistung
-
Negative Parameter
(Erzeuger)