Specifications
6
a. poor DC wiring 
Use proper cable and 
make solid connections 
6. Low battery alarm on all 
the time and VOLTS 
indicator below 10.5V ( 21V 
for 2500W/24V inverter ) 
b.Poor battery condition  Change battery or use 
new battery 
7. No voltage output , OVER 
TEMP indicator light and 
load in excess of 2500W/250 
amperes current input ( or 
125A for 2500W / 24V 
inverter) 
Thermal shutdown  Allow inverter cool down 
and reduce load if 
continuous operation 
required 
8. No voltage output , OVER 
TEMP indicator light and 
load less than 2500W/250 
amperes current input ( or 
125A for 2500W/24V 
inverter ) 
Thermal shutdown  Make sure ventilation 
openings in inverter are 
not blocked and reduce 
ambient temperature . 
a. Short circuit or wiring error
Check AC wiring for short 
circuit or improper polarity
9. No voltage output and 
OVER LOAD indicator light 
Very high power load  Remove or reduce load 
If after the above easy troubleshooting , this inverter still doesn’t work , please 
return it to us or have a qualified electrician to check and replace. Don’t open the 
case or cut out the cord. 
7. CAUTION: 
Do not use the inverter with the following rechargeable appliances: 
Two particular types of chargers for small nickel cadmium batteries can be damaged if 
connected to the inverter: 
a. Small battery operated appliances such as flashlights , razors and nightlights that can be 
plugged directly into the AC receptacle to recharge . 
b. Certain battery chargers for battery packs used in hand power tool. These chargers will 
have a warning label starting that dangerous voltages are present at the battery terminals. 
This problem doesn’t occur with the vast majority of battery operating equipment . Most of 
these equipments use a separate charger or transformer that is plugged into the AC 
receptacle and produces the lower voltage output . If the label on the AC adaptor or charger 
states that produces the low AC or DC voltage output (less than 30 volts), the inverter will 
power this adaptor or charger safely without trouble . 
USE THE CORRECT SIZE AND TYPE OF BATTERY! 
For most applications of 2500W inverter it is recommended to use one deep cycle battery or 
more in parallel. More capacity is better because there will be more reserve capacity to 
prevent the battery to be discharged too far. 