Disconnect each power cord from the power source.
Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4. Remove the access panel.
5. Using the labels on the cable, connect the cables to the riser.
6. Install the tertiary riser cage.
7. Connect the cable to the drive backplane.
The installation is complete.
Installing the 8NVMe slimSAS riser option
The 8NVMe slimSAS riser can be installed in the primary or secondary position.
Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit
T-10 Torx screwdriver
Procedure
1. Power down the server .
2. Do one of the following:
Disconnect each power cord from the power source.
Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4. Remove the access panel.
5. Using the labels on the cable, connect the cables to the riser.
6. Do one of the following:
To install the riser in the primary position:
90 Installing the 8NVMe slimSAS riser option