9. Install drives or drive blanks.
10. Install the secondary rear wall or a riser cage.
11. Cable the drive backplane.
12. Install the access panel.
13. Slide the server into the rack.
14. Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Power up the server.
The installation is complete.
Installing a rear 3LFF SAS/SATA drive cage
Before installing this option, the front bays must be fully populated with 12 LFF drives. High-performance fans
must be installed in all fan bays.
Prerequisites
Before installing this option, be sure that you have the following:
T-10 Torx screwdriver
The components included with the hardware option kit
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack.
Remove the server from the rack .
4. Remove the access panel.
5. If installed, remove the secondary riser cage. The secondary riser cage is not supported with a three-bay
LFF rear configuration.
82 Installing a rear 3LFF SAS/SATA drive cage