7. Install the access panel.
8. Install the server in the rack.
9. Connect each power cord to the server.
10. Connect each power cord to the power source.
11. Power up the server.
Use the BIOS/Platform Configuration (RBSU) in the UEFI System Utilities to configure the memory mode.
For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display
combined LED descriptions."
Controller options
The server supports the following storage controllers:
Embedded controllers
Enabled through System Utilities and configured through HPE Smart Storage Administrator (Intelligent
Provisioning)
Type-a controllers
Type-a controllers install in the type-a smart array connector.
Type-p controllers
Type-p controllers install in a PCIe expansion slot
Installing a storage controller
Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
62 Controller options