User Manual
Table Of Contents
- HPE ProLiant DL380 Gen10 Server User Guide
- Contents
- Component identification
- Operations
- Powering up the server
- Power down the server
- Extend the server from the rack
- Extending the server from the rack
- Removing the server from the rack
- Installing the server into the rack
- Remove the access panel
- Installing the access panel
- Removing the fan cage
- Installing the fan cage
- Removing the air baffle or midplane drive cage
- Installing the air baffle
- Removing a riser cage
- Removing a riser slot blank
- Removing the hard drive blank
- Releasing the cable management arm
- Accessing the Systems Insight Display
- Setup
- Hardware options installation
- Product QuickSpecs
- Introduction
- Installing the bezel and bezel lock
- Power supply options
- Drive options
- Fan options
- Memory options
- Controller options
- Installing a Universal Media Bay
- Drive cage options
- Installing a front 8NVMe SSD Express Bay drive cage
- Installing a front 6SFF SAS/SATA + 2NVMe Premium drive cage
- Installing a front 8SFF SAS/SATA drive cage in box 1
- Installing a front 8SFF SAS/SATA drive cage in box 2
- Installing a front 2SFF NVMe/SAS/SATA Premium drive cage
- Installing a midplane 4LFF SAS/SATA drive cage
- Installing a rear 2SFF SAS/SATA drive cage in the primary or secondary riser
- Installing a rear 2SFF SAS/SATA drive cage over the power supplies
- Installing a rear 3LFF SAS/SATA drive cage
- Riser and riser cage options
- Expansion slots
- Installing an intrusion detection switch
- Installing a Smart Storage Battery
- Installing a rear serial port interface
- Installing a Systems Insight Display
- Installing a FlexibleLOM adapter
- Installing a 1U or high-performance heatsink
- Installing a processor
- HPE Trusted Platform Module 2.0 Gen10 Option
- Cabling
- HPE ProLiant Gen10 DL Servers Storage Cabling Guidelines
- Cabling diagrams
- Cable routing: Front 2SFF drive option for SFF
- Cable routing: Front 2SFF drive option for LFF
- Cable routing: Front 2SFF drive options (3 position cable)
- Cable routing: Front 8SFF drive options
- Cable routing: Front 8SFF NVMe/SAS premium drive option
- Cable routing: Front 8SFF NVMe drive options
- Cable routing: Front 2SFF NVMe drive option for SFF
- Cable routing: Front 2SFF NVMe drive option for LFF
- Cable routing: Midplane 4LFF drive option
- Cable routing: Rear 3LFF drive option
- Cable routing: Rear 2SFF drive options
- Cable routing: HPE 12G SAS Expander to a controller
- Cable routing: Systems Insight Display
- Software and configuration utilities
- Server mode
- Product QuickSpecs
- Active Health System Viewer
- HPE iLO 5
- Intelligent Provisioning
- Management Security
- Scripting Toolkit for Windows and Linux
- UEFI System Utilities
- HPE Smart Storage Administrator
- USB support
- Redundant ROM support
- Keeping the system current
- Troubleshooting
- Safety, warranty, and regulatory information
- Specifications
- Support and other resources
- Documentation feedback
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers,
or blanks installed. If the server supports hot-plug components, minimize the amount of time the access
panel is open.
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
• Extend the server from the rack.
• Remove the server from the rack.
4. Remove the access panel.
5. Do one of the following:
• Remove the air baffle.
• Remove the 4LFF midplane drive cage:
a. Disconnect all cables.
b. Remove all drives.
Be sure to note the location of each drive.
c. Remove the drive cage.
CAUTION:
Do not drop the drive cage on the system board. Dropping the drive cage on the system board
might damage the system or components. Remove all drives and use two hands when
installing or removing the drive cage.
38 Operations