User Manual
Table Of Contents
- HPE ProLiant DL380 Gen10 Server User Guide
- Contents
- Component identification
- Operations
- Powering up the server
- Power down the server
- Extend the server from the rack
- Extending the server from the rack
- Removing the server from the rack
- Installing the server into the rack
- Remove the access panel
- Installing the access panel
- Removing the fan cage
- Installing the fan cage
- Removing the air baffle or midplane drive cage
- Installing the air baffle
- Removing a riser cage
- Removing a riser slot blank
- Removing the hard drive blank
- Releasing the cable management arm
- Accessing the Systems Insight Display
- Setup
- Hardware options installation
- Product QuickSpecs
- Introduction
- Installing the bezel and bezel lock
- Power supply options
- Drive options
- Fan options
- Memory options
- Controller options
- Installing a Universal Media Bay
- Drive cage options
- Installing a front 8NVMe SSD Express Bay drive cage
- Installing a front 6SFF SAS/SATA + 2NVMe Premium drive cage
- Installing a front 8SFF SAS/SATA drive cage in box 1
- Installing a front 8SFF SAS/SATA drive cage in box 2
- Installing a front 2SFF NVMe/SAS/SATA Premium drive cage
- Installing a midplane 4LFF SAS/SATA drive cage
- Installing a rear 2SFF SAS/SATA drive cage in the primary or secondary riser
- Installing a rear 2SFF SAS/SATA drive cage over the power supplies
- Installing a rear 3LFF SAS/SATA drive cage
- Riser and riser cage options
- Expansion slots
- Installing an intrusion detection switch
- Installing a Smart Storage Battery
- Installing a rear serial port interface
- Installing a Systems Insight Display
- Installing a FlexibleLOM adapter
- Installing a 1U or high-performance heatsink
- Installing a processor
- HPE Trusted Platform Module 2.0 Gen10 Option
- Cabling
- HPE ProLiant Gen10 DL Servers Storage Cabling Guidelines
- Cabling diagrams
- Cable routing: Front 2SFF drive option for SFF
- Cable routing: Front 2SFF drive option for LFF
- Cable routing: Front 2SFF drive options (3 position cable)
- Cable routing: Front 8SFF drive options
- Cable routing: Front 8SFF NVMe/SAS premium drive option
- Cable routing: Front 8SFF NVMe drive options
- Cable routing: Front 2SFF NVMe drive option for SFF
- Cable routing: Front 2SFF NVMe drive option for LFF
- Cable routing: Midplane 4LFF drive option
- Cable routing: Rear 3LFF drive option
- Cable routing: Rear 2SFF drive options
- Cable routing: HPE 12G SAS Expander to a controller
- Cable routing: Systems Insight Display
- Software and configuration utilities
- Server mode
- Product QuickSpecs
- Active Health System Viewer
- HPE iLO 5
- Intelligent Provisioning
- Management Security
- Scripting Toolkit for Windows and Linux
- UEFI System Utilities
- HPE Smart Storage Administrator
- USB support
- Redundant ROM support
- Keeping the system current
- Troubleshooting
- Safety, warranty, and regulatory information
- Specifications
- Support and other resources
- Documentation feedback
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Rated input current
5.8 A at 100 VAC
2.8 A at 200 VAC
2.4 A at 240 VDC for China
only
Maximum rated input power
580 W at 100 VAC
560 W at 200 VAC
576 W at 240 VDC for China
only
BTUs per hour
1979 at 100 VAC
1911 at 200 VAC
1965 at 240 VDC for China
only
Power supply output
Rated steady-state power
500 W at 100 VAC to 127 VAC
input
500 W at 200 VAC to 240 VAC
input
500 W at 240 VDC input for
China only
Maximum peak power
500 W at 100 VAC to 127 VAC
input
500 W at 200 VAC to 240 VAC
input
500 W at 240 VDC input for
China only
HPE 800W Flex Slot Platinum Hot-plug Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 127 VAC
200 to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240VDC
Table Continued
HPE 800W Flex Slot Platinum Hot-plug Power Supply 149