User Manual
Table Of Contents
- HPE ProLiant DL380 Gen10 Server User Guide
- Contents
- Component identification
- Operations
- Powering up the server
- Power down the server
- Extend the server from the rack
- Extending the server from the rack
- Removing the server from the rack
- Installing the server into the rack
- Remove the access panel
- Installing the access panel
- Removing the fan cage
- Installing the fan cage
- Removing the air baffle or midplane drive cage
- Installing the air baffle
- Removing a riser cage
- Removing a riser slot blank
- Removing the hard drive blank
- Releasing the cable management arm
- Accessing the Systems Insight Display
- Setup
- Hardware options installation
- Product QuickSpecs
- Introduction
- Installing the bezel and bezel lock
- Power supply options
- Drive options
- Fan options
- Memory options
- Controller options
- Installing a Universal Media Bay
- Drive cage options
- Installing a front 8NVMe SSD Express Bay drive cage
- Installing a front 6SFF SAS/SATA + 2NVMe Premium drive cage
- Installing a front 8SFF SAS/SATA drive cage in box 1
- Installing a front 8SFF SAS/SATA drive cage in box 2
- Installing a front 2SFF NVMe/SAS/SATA Premium drive cage
- Installing a midplane 4LFF SAS/SATA drive cage
- Installing a rear 2SFF SAS/SATA drive cage in the primary or secondary riser
- Installing a rear 2SFF SAS/SATA drive cage over the power supplies
- Installing a rear 3LFF SAS/SATA drive cage
- Riser and riser cage options
- Expansion slots
- Installing an intrusion detection switch
- Installing a Smart Storage Battery
- Installing a rear serial port interface
- Installing a Systems Insight Display
- Installing a FlexibleLOM adapter
- Installing a 1U or high-performance heatsink
- Installing a processor
- HPE Trusted Platform Module 2.0 Gen10 Option
- Cabling
- HPE ProLiant Gen10 DL Servers Storage Cabling Guidelines
- Cabling diagrams
- Cable routing: Front 2SFF drive option for SFF
- Cable routing: Front 2SFF drive option for LFF
- Cable routing: Front 2SFF drive options (3 position cable)
- Cable routing: Front 8SFF drive options
- Cable routing: Front 8SFF NVMe/SAS premium drive option
- Cable routing: Front 8SFF NVMe drive options
- Cable routing: Front 2SFF NVMe drive option for SFF
- Cable routing: Front 2SFF NVMe drive option for LFF
- Cable routing: Midplane 4LFF drive option
- Cable routing: Rear 3LFF drive option
- Cable routing: Rear 2SFF drive options
- Cable routing: HPE 12G SAS Expander to a controller
- Cable routing: Systems Insight Display
- Software and configuration utilities
- Server mode
- Product QuickSpecs
- Active Health System Viewer
- HPE iLO 5
- Intelligent Provisioning
- Management Security
- Scripting Toolkit for Windows and Linux
- UEFI System Utilities
- HPE Smart Storage Administrator
- USB support
- Redundant ROM support
- Keeping the system current
- Troubleshooting
- Safety, warranty, and regulatory information
- Specifications
- Support and other resources
- Documentation feedback
Specifications
Environmental specifications
Specification Value
Temperature range
1
—
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing) —
Operating
Minimum to be the higher (more moisture) of -12°C
(10.4°F) dew point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90%
relative humidity
Nonoperating
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft)
to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour
(36°F per hour). The upper limit and rate of change might be limited by the type and number of options
installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
• 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C
per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
• 40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per
every 410 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise
website.
Mechanical specifications
Specification Value
Height 8.73 cm (3.44 in)
Depth, SFF 67.94 cm (26.75 in)
Depth, LFF 73.02 cm (28.75 in)
Width 44.54 cm (17.54 in)
Weight, SFF minimum 14.9 kg (32.75 lbs)
Weight, SFF maximum 19.5kg (43.00 lbs)
Weight, LFF minimum 17.1 kg (37.75 lbs)
Weight, LFF maximum 24.5 kg (54 lbs)
The SFF configuration includes the following components: