User Manual
QuickSpecs
HPE OfficeConnect 1920 Switch Series
Technical Specifications
Page
16
Notes
SFP ports and copper ports work simultaneously, independent of each other, to provide a total of 28
Gigabit switching ports.
Services
Refer to the Hewlett Packard Enterprise website at http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.
HPE OfficeConnect 1920 24G PoE+ (370W) Switch (JG926A)
I/O ports and slots
24 RJ-45 auto-negotiating 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type
100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3af PoE, IEEE 802.3at)
4 SFP 100/1000 Mbps slots (IEEE 802.3u Type 100BASE-FX, IEEE 802.3z Type 1000BASE-X
Supports a maximum of 24 autosensing 10/100/1000 ports plus 4 SFP 100/1000 slots
Additional ports and
slots
1 RJ-45 console port to access limited CLI port
Physical characteristics
Dimensions
17.32(w) x 10.24(d) x 1.73(h) in (44 x 26 x 4.4 cm) (1U height)
Weight
7.5 lb (3.4 kg)
Memory and processor
MIPS @ 500 MHz, 32 MB flash, 128 MB SDRAM; packet buffer size: 512 KB
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
Performance
100 Mb Latency
< 5 µs
1000 Mb Latency
< 5 µ
s
Throughput
up to 41.7 Mpps (64-byte packets)
Routing/Switching
capacity
56 Gbps
Routing table size
32 entries (IPv4), 32 entries (IPv6)
MAC address table size
8192 entries
Reliability
MTBF (years)
65.78
Environment
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative
humidity
10% to 90%, noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
10% to 95%, noncondensing
Altitude
up to 16,404 ft (5 km)
Acoustic
Low-speed fan: 44.9 dB, High-speed fan: 53.3 dB; ISO 7779
Electrical characteristics
Frequency
50/60 Hz
AC voltage
100 - 240 VAC
Maximum power rating
474 W
PoE power
370 W PoE+
Notes
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure
with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.
PoE power is the power supplied by the internal power supply. It is
dependent on the type and quantity of power supplies and may be
supplemented with the use of an external power supply (EPS
).
When supplemented with the use of an HP RPS1600 Redundant Power
System, up to 795 W of PoE+ can be supplied. Unit max. power
consumption with RPS is 833 W.