User Manual

Humidity (Operation)
Humidity (Operation)Humidity (Operation)
Humidity (Operation)
20% to 80% (non-condensing)
Humidity
HumidityHumidity
Humidity
(Non-operating)
(Non-operating)(Non-operating)
(Non-operating)
5% to 95%, 38.7 C maximum wet bulb temperature with no cosmetic
damage
Operating Altitude
Operating AltitudeOperating Altitude
Operating Altitude
Up to 1500m above sea level, 0-40 C
Transit and Storage
Transit and StorageTransit and Storage
Transit and Storage
Altitude
AltitudeAltitude
Altitude
Up to 49,000 ft (15,000 m) above sea level
Audible Noise
Audible NoiseAudible Noise
Audible Noise
Normal mode: Less than 40 dBA max measured from 1 meter
Charging/Fan on/AVR/Inverter mode: Less than 50 dBA max measured from
1 meter
Safety
SafetySafety
Safety
Compliant (not certified) with IEC 62040-1-1 including IEC 60950-1
Emissions
EmissionsEmissions
Emissions
Compliant (not certified) EN62040-2 Class A
Operating Systems
Operating SystemsOperating Systems
Operating Systems
Compatibility
CompatibilityCompatibility
Compatibility
Supports both 32 bit and 64 bit Operating systems:
Windows
Windows Server 2003 Ent - SP2
Windows XP
Windows Vista
Windows Server 2008
Linux
RedHat 5 - U1
SLES 10 - SP1
Estimated Backup Times Chart (In Minutes)
Estimated Backup Times Chart (In Minutes)Estimated Backup Times Chart (In Minutes)
Estimated Backup Times Chart (In Minutes)
T1000v
T1000vT1000v
T1000v
Load, percent
Load, percentLoad, percent
Load, percent
Load, Watts
Load, WattsLoad, Watts
Load, Watts
Estimated battery runtime at 100% battery
Estimated battery runtime at 100% batteryEstimated battery runtime at 100% battery
Estimated battery runtime at 100% battery
charge
chargecharge
charge
50%
300
8 minutes
100%
600
3 minutes
NOTE:
NOTE: NOTE:
NOTE:
Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation. Unix is a registered trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
QuickSpecs
HP T1000v Uninterruptible Power Supply (UPS)
HP T1000v Uninterruptible Power Supply (UPS)HP T1000v Uninterruptible Power Supply (UPS)
HP T1000v Uninterruptible Power Supply (UPS)
Technical Specifications
DA - 13130 Worldwide — Version 3 — June 20, 2011