Troubleshooting Without Diagnostics
Solving Display Problems
Solving Display Problems
Problem Cause Solution
Blank screen (no video). The cable connections
are not correct.
Check the cable connections from
the monitor to the workstation and to
the electrical outlet.
Screen blanking utility
installed or energy
saver features enabled.
Press any key or click the mouse
button and, if set, type your
password.
System ROM is bad;
system is running in
FailSafe Boot Block
mode (indicated by
eight beeps).
Reflash the ROM using a ROMPaq
diskette.
Fixed-sync monitor will
not sync at the
resolution chosen.
Ensure that the monitor can accept
the same horizontal scan rate as the
resolution chosen.
Workstation is in
standby mode.
Press the power button to resume
from standby mode.
Ć
CAUTION: When attempting to resume from standby mode, do not hold down the
power button for more than four seconds. Otherwise, the workstation will shut down
and you will lose your data.
Monitor cable plugged
into the wrong
connector.
If the workstation system has both
an
integrated graphics connector
and an AGP card connector, plug
the monitor cable into the AGP card
connector.
Monitor settings in the
workstation are not
compatible with the
monitor.
1. Restart the workstation and
press F8 during startup when
you see āPress F8ā in the bottom
right corner of the screen.
2. Using the keyboard arrow keys,
select Enable VGA Mode
and press Enter.
3. In Windows Control Panel,
double-click the Display icon
and select the Settings tab.
4. Use the sliding control to reset
the resolution.