Command Reference Guide
44 CHAPTER 3: SYSTEM SERVICE COMMANDS
See Also
clear system on page 39
set system contact on page 54
set system countrycode on page 54
set system ip-address on page 57
set system location on page 58
set system name on page 58
Fan status Operating status of the WX switch’s three cooling fans:
OK — Fan is operating.
Failed — Fan is not operating. MSS sends an alert to
the system log every 5 minutes until this condition is
corrected.
Fan 1 is located nearest the front of the chassis, and fan 3
is located nearest the back.
Temperature Status of temperature sensors at three locations in the WX:
ok — Temperature is within the acceptable range of
0° C to 50° C (32° F to 122° F).
Alarm — Temperature is above or below the
acceptable range. MSS sends an alert to the system log
every 5 minutes until this condition is corrected.
PSU Status Status of the lower and upper power supply units:
missing — Power supply is not installed or is
inoperable.
DC ok — Power supply is producing DC power.
DC output failure — Power supply is not producing
DC power. MSS sends an alert to the system log every
5 minutes until this condition is corrected.
AC ok — Power supply is receiving AC power.
AC not present — Power supply is not receiving AC
power.
Memory Current size (in megabytes) of nonvolatile memory (NVRAM)
and synchronous dynamic RAM (SDRAM), plus the percentage
of total memory space in use, in the following format:
NVRAM size /SDRAM size (percent of total)
Total Power Over
Ethernet
Total power that the device is currently supplying to its
directly connected MAP access points, in watts.
Table 7 display system output (continued)
Field Description