Command Reference Guide

332 CHAPTER 9: MANAGED ACCESS POINT COMMANDS
holddown — Minimum number of seconds a radio must remain on its
current channel setting before RF Auto-Tuning is allowed to change
the channel. You can specify from 0 to 65535 seconds.
Defaults — The default RF Auto-Tuning channel holddown is 900
seconds.
Access — Enabled.
History —Introduced in MSS Version 3.0.
Usage — The channel holddown applies even if RF anomalies occur that
normally cause an immediate channel change.
Examples — The following command changes the channel holddown
for radios in radio profile rp2 to 600 seconds:
WX4400# set radio-profile rp2 auto-tune channel-holddown 600
success: change accepted.
See Also
set radio-profile auto-tune channel-config on page 330
set radio-profile auto-tune channel-interval on page 332
set radio-profile
auto-tune
channel-interval
Sets the interval at which RF Auto-Tuning decides whether to change the
channels on radios in a radio profile. At the end of each interval, MSS
processes the results of the RF scans performed during the previous
interval, and changes radio channels if needed.
Syntax
set radio-profile name auto-tune channel-interval
seconds
name — Radio profile name.
seconds Number of seconds RF Auto-Tuning waits before
changing radio channels to adjust to RF changes, if needed. You can
specify from 0 to 65535 seconds.
Defaults — The default channel interval is 3600 seconds (one hour).
Access — Enabled.
History —Introduced in MSS Version 3.0.