CLI Reference Guide
Changing Monitoring Settings 491
7 To enable the monitoring service to track client connection failures, select
Collect client connection failure traps.
This option enables the monitoring service to collect data from the
following traps generated by monitored WX switches:
ClientAssociationFailure, ClientAuthenticationFailure,
ClientAuthorizationFailure, and ClientDot1xFailure. This option is
disabled by default.
d To enable the monitoring service to track client connections and keep
roaming histories for clients, select Collect client connection &
roaming traps.
This option enables the monitoring service to collect data from the
following traps generated by monitored WX switches:
ClientAuthorizationSuccess, ClientCleared, ClientDeAssociation, and
ClientRoaming. This option is disabled by default.
8 To change settings for monitoring of RF information, perform the
following steps. These options control data sent to the RF Monitor and RF
Trends windows of the Monitor tab.
a Select Enable RF trending. This option is disabled by default.
The Polling Interval is 5 minutes and cannot be changed.
b To enable the monitoring service to track channel and power changes
caused by RF Auto-Tuning, and also track countermeasures, select
Collect radio activity traps.
c To change the threshold for a threshold crossing alert (TCA), change
the value in the Low SNR, Max clients per AP, or Max Receiver
Adjustment listbox:
ξ Low SNR specifies how low the signal-to-noise ratio (SNR) can be
for a radio without triggering a TCA. You can specify from 0 to 60
decibels (dB). The default is 20 dB.
ξ Max clients per AP specifies the maximum number of clients that
can be associated with a MAP without triggering a TCA. You can
specify from 5 to 50 clients. The default is 30 clients.
ξ Max Receiver Adjustment specifies the maximum amount a radioβs
hearing sensitivity can increase without triggering a TCA. You can
specify from 0 to 20 decibels (dB). The default is 6 dB.