DescriptionMessageEvent
ID
This event is logged when the DSM detects an unrecover-
able failure of a multipath capable disk. Although the disk
may be visible to the system, the data on the disk may
not be accessible. Please check the status of the multipath
capable disk at the array end. X represents the serial
number of the disk.
An unrecoverable failure has
occurred on multipath capable
disk X. The data on this disk
may be inaccessible.
308
The DSM cannot manage multipath capable disk X (SCSI
address Y) due to an internal error.
The DSM cannot manage mul-
tipath capable disk X (SCSI
address Y) due to an internal
error.
309
This event is logged when DSM detects that the path with
SCSI address Y is inconsistent and is moved to failed state.
X represents the serial number of the disk. A reboot of the
system is recommended to overcome this inconsistent state.
The DSM detected an inconsist-
ency in the path (SCSI ad-
dress Y) to the multipath
capable disk X. This path has
been marked as failed.
310