HP MPIO Full Featured DSM for P9000 family of Disk Arrays 4.02.00 installation and reference guide (AA-RVJ6M-TE, October 2010)
The hpprutil devices command displays details of reservations on the devices as shown in the
following example. If there are no devices present, the following message is displayed: No Devices
Found.
Example:
hpprutil devices
NT Disk#ReservationSCSI AddressDevice NameDevice#
Disk6PR4.0.3.0HP OPEN-V1
Disk7PR4.0.3.1HP OPEN-V2
hpprutil clear device
Syntax: hpprutil clear device=x
Syntax: hpprutil clear device=m n
The hpprutil clear device command clears the reservation present on device x, or clears the
reservation present on devices starting from m to n (both inclusive), depending on the input parameter
specified.
Example:
hpprutil clear device=1
The requested operation is in progress. Please wait.
HPPRUTIL will attempt to clear the reservation on device 1.
Are you sure you want to continue (y/n)? y
Attempting to clear the reservation on device 1... Successfully cleared the re-
servation on device.
hpprutil clear device=1 2
The requested operation is in progress. Please wait.
HPPRUTIL will attempt to clear the reservation on device 1 to 2.
Are you sure you want to continue (y/n)? y
Attempting to clear the reservation on device 1... Successfully cleared the re-
servation on device.
Attempting to clear the reservation on device 2... Successfully cleared the re-
servation on device.
hpprutil help
Syntax: hpprutil help
The hpprutil help command displays help information for hpprutil.
HP MPIO Full Featured DSM for P9000 family of Disk Arrays 4.02.00 installation and reference
guide 41