installation and reference guide HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.02.00 (AA-RW8AF-TE, March 2009)
Disk 2Policy:SQST-Subset
ALB:N/AP.B.T.L:3.0.0.13
P.B.T.LRTPHBA Slot#StateController Port#Path#
3.0.2.13000100027ActiveP56350GX3R10F6-11
4.0.2.13000100026AvailableP56350FX3RQA03-12
hpdsm paths device
Syntax: hpdsm paths device=x
The hpdsm paths device command displays information about the paths available for device x,
as shown in the following example.
NOTE:
• The P.B.T.L. column shows the device port, bus, target, and LUN.
• The RTP column shows the target port information as defined by SCSI-3 specification.
• The Controller Port# column shows the controller serial number followed by target port number.
hpdsm paths device=1
P.B.T.LRTPHBA Slot#StateController Port#Path#
3.1.3.1000100014ActiveP56350FX3Q5006-11
4.1.3.1000200024AvailableP56350GX3RI0F6-12
hpdsm set device policy
Syntax: hpdsm set device=x policy=policy
Syntax: hpdsm set device=all policy=policy
The hpdsm set device policy command sets the load-balancing policy for device x or for all
device, depending on the input parameter specified.
The following example demonstrates the information displayed by the hpdsm set device policy
command.
HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.02.00 27